Introduction 6
1.4 Indicator Operations
Basic 880 operations are summarized below:
1.4.1 Toggle Gross/Net Mode
1. Press to toggle the display mode between gross and net.
Net mode is available when a tare value has been entered or acquired,
(NET = GROSS minus TARE). If tare has not been entered or acquired, the
display remains in gross mode. LEDs next to Gross or Net indicates the
current mode.
1.4.2 Toggle Units
1. Press to switch between primary and secondary units. The current
units LED will be lit.
1.4.3 Zero Scale
1. In gross mode, remove all weight from the scale and wait for the LED
to light.
2. Press . The LED lights to indicate the scale is zeroed.
The scale must be stable and within the configured zero range, for the
scale to be zeroed. If the scale cannot be zeroed, NOZERO will display.
1.4.4 Acquire Tare
1. Place container on scale and wait for the LED to light.
2. Press to acquire the tare weight of the container. Net weight is
displayed and the T LED lights to show the tare value was entered.
1.4.5 Remove Stored Tare Value
1. Remove all weight from the scale and wait for the LED to light.
2. The display should read zero and the LED should be lit, zero the
scale if needed.
3. Press (or, in OIML mode ). Display shifts to gross weight
and the Gross LED is lit.
If keyed tare is allowed, press to open the keyed tare prompt. To
clear the tare press again.
0