Installation 11
2.2 Panel Mount Installation
6.0
"
5.3
"
4.0
"
3.0
"
5.0
"
Note
The controller can be mounted to the display DIN rail or mounted remotely up to 250 ft away from display.
Figure 2-1. 880 Panel Mount Dimensions
Use the Din Rail Mount plate as a template (see Figure 2-2) to drill the mounting holes in the panel for the stainless
steel panel mount enclosure. See Figure 2-1 for enclosure dimensions.
1. Mark panel for installation using the DIN rail backer plate
and drill the five holes required for mounting.
4.25"
3.38
"
4.00"
2.25"
1.13
"
6.00"
0.88
"
0.88"
5/32
" Ø
7/8
" Ø
Use DIN Rail Mount
Plate as a template for
drilling mounting holes
in panel.
Figure 2-2. Pattern for Cutting Holes
2. Install the gasket on the display assembly. It must be seated correctly on display before mounting to ensure
tight seal.
3. Align the display assembly to the front and the DIN rail
mounting plate to the back of the panel with the
holes cut in step 1.
4. Secure the display and mounting plate to the panel using the four 6-32 Kep nuts (PN 14621) provided.