118677CounterpartCounting Scale IndicatorVersion 1.0User ManualTo be the best by every measure®
4 Counterpart User ManualFigure 1-1. Numeric Keypad1.5 Tare RecallWhen a stored tare is displayed, Net annunciators will be turned on. To display a st
Counterpart User Manual - Introduction 51.9 Indicator OperationsBasic Counterpart operations are summarized below.Toggle Gross/NetPress the GROSS/NET
6 Counterpart User Manual2.0 InstallationCounterpart is available in different configurations from just the indicator display to the display and count
Counterpart User Manual - Installation 72.2 LevelingSelect a location for the Counterpart that is reasonably level and free of vibrations and air curr
8 Counterpart User Manual2.7 Cable GroundingExcept for the power cord, all cables should be grounded against the scale enclosure. Do the following to
Counterpart User Manual - Installation 92.7.3 Network Connection to CounterpartCounterpart has an onboard Ethernet connection. It’s wireless connectiv
10 Counterpart User ManualFigure 2-3. Counterpart CPU BoardIf the RESET button on the CPU board is pressed, the scale will perform a reboot.Jumper Des
Counterpart User Manual - Installation 112.12 Indicator Replacement Parts and Assembly DrawingsFigure 2-4. Counterpart Indicator Replacement PartsRef
12 Counterpart User ManualFigure 2-5. Counterpart Front View
Counterpart User Manual - Installation 13Figure 2-6. Counterpart Assembly and Components
14 Counterpart User ManualFigure 2-7. Counterpart DimensionsFigure 2-8. Counterpart Rear and Side Dimensions
Counterpart User Manual - Configuration 153.0 Configuration3.1 Front Panel ConfigurationTo set up and configure the Counterpart counting Scale, you wi
16 Counterpart User ManualVarious keys are used as directional keys to navigate through the menus (see Figure 3-2). The SAMPLE ( ) and PRINT ( ) keys
Counterpart User Manual - Configuration 173.4 Audit MenuThe audit menu accesses audit trail support. It provides tracking information for configuratio
18 Counterpart User Manual3.5 Menu Structures and Parameter DescriptionsThe Counterpart scale can be configured using a series of menus accessed throu
Counterpart User Manual - Configuration 19Figure 3-6. Setup Menu: Scale SubmenuFEATUR PFORMTSERIAL DIGIOXXXXXXXIDDISPLAYTESTSETUPAUDIT CALIBRSCALESFOR
20 Counterpart User ManualSETUP MenuParameter Choices DescriptionLevel 3 submenuSCALES 1 AND 2 Allows configuration and calibration of each scaleLevel
Counterpart User Manual - Configuration 21DFSENS 4OUT2OUT8OUT16OUT32OUT64OUT128OUTDigital filter cutout sensitivity. Specifies the number of consecuti
22 Counterpart User ManualLevel 5 submenus - FormatPRIMRY UNITSDECPNTDSPDIVAllows you to set the primary units, decimal point format, and display divi
Counterpart User Manual - Configuration 233.6.2 SCALE 3 SubmenuFigure 3-7. Scale 3 Serial MenuSCALE 3 SubmenuParameter Choices DescriptionFormat Subm
Contents1.0 Introduction...
24 Counterpart User Manual3.6.3 FEATUR SubmenuFigure 3-8. FEATUR Submenu NEGCOUNTSAMPLQTY LOTUPDT1ONOFFCOUNTREGIONUIDCONSC#PASSWDSOFTKEYSKEYLCK1025SCA
Counterpart User Manual - Configuration 25 FEATUR MenuParameter Choices DescriptionLevel 3 submenus - FeatureCOUNT NEGCOUNTSAMPLEQTYINSFSMPLLOTUPDTSCL
26 Counterpart User ManualRECALL ONOFFON allows the Tare, Zero, and Units values to be maintained across a power cycle. Over/Under/Target/ID values ar
Counterpart User Manual - Configuration 27DISPMODE CountWeighUnit WeightDisplay mode. This chooses the value to be displayed as large in viewing windo
28 Counterpart User ManualSK1-12 BLANKTIMEDATECLR TARDSPTARDSP ACCSCL SELCODELOTPRINT PLTSWAP DSPINOUTCLR CNTOTAL +TOTAL -CLR TTLLabels softkeys for a
Counterpart User Manual - Configuration 293.6.4 FEATUR Menu, REGULA / INDUST SubmenuFigure 3-9. FEATUR Menu, REGULA/INDUST SubmenuDFORMT MMDDY4DDMMY4Y
30 Counterpart User ManualKTARE YES NOAlways allow keyed tare.MTARE REPLACREMOVENOTHINMultiple tare action.NTARE NOYESAllow negative or zero tare.CTAR
Counterpart User Manual - Configuration 313.6.5 Serial, PFORMT, DIG I/O, VERS SubmenusFigure 3-10. Serial, PFORMT, DIG I/O, VERS SubmenusSCALES FEATUR
32 Counterpart User ManualSETUP MenuParameter Choices DescriptionLevel 2 submenusSCALE See Section 3.6.1 on page 18 Configure scale settings. See the
Counterpart User Manual - Configuration 33Level 3 submenus - Under the Level 2 Version FeatureSOFTWR V1.XX Displays the software versionREG LR, V 1.XX
ii Counterpart User Manual4.1 Front Panel Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34 Counterpart User ManualIND SCALE BAUDBITSSTOP BITSTERMINEOLDYSFMTSets up the transmission information for the industrial scale parameter.SETUP Menu
Counterpart User Manual - Configuration 353.7 Calibration MenuSee Section 4.0 on page 39 for calibration procedures. The Calibration menu can be prote
36 Counterpart User Manual3.8 Test MenuFigure 3-12. Test MenuTEST MenuParameter Choices DescriptionLevel 2 submenusA/D AD1AD2EXCVACGives details of cu
Counterpart User Manual - Configuration 373.9 Display MenuThere are three display settings on the Counterpart. Figure 3-13. DISPLAY MenuSetting the di
38 Counterpart User Manual3.10 ID MenuThe ID menu displays parameters for registers from 1 to 150. Sub-parameters are shown below.Figure 3-14. ID Menu
Counterpart User Manual - Calibration 394.0 CalibrationThe Counterpart can be calibrated using the front panel, EDP commands, or Revolution®. Calibrat
40 Counterpart User ManualFive-point linearization - COMING SOON Rezero - COMING SOON4.2 EDP Command CalibrationTo calibrate the indicator using EDP c
Counterpart User Manual - Calibration 414.4 More About CalibrationThe following topics provide additional information about compensating for environme
42 Counterpart User Manual5.0 Scale OperationsThe following paragraphs contain detailed operator instructions for Counterpart. Included are instructio
Counterpart User Manual - Scale Operations 435.3 Toggling Between Gross and NetTo toggle between net and gross weight, a tare value must be entered in
9.5 Custom Stream Formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689.6 D
44 Counterpart User Manual5.4.1 Unit Weight Operation by SamplingUnit weight operation by sampling is accomplished by placing a 10 piece sample on the
Counterpart User Manual - Scale Operations 45Counting Out of a Full Container - See Total Amount Remaining in the ContainerTo carry out this operation
46 Counterpart User Manual4. When you have reached the REG number you want to set, press to select that register number.5. Press and enter the COD
Counterpart User Manual - Scale Operations 475.5.3 Adding an ID From Count Mode1. Press the CODE softkey.2. Add in the ID number.3. If the ID number i
48 Counterpart User Manual5.5.5 WeighVaultWeighVault is a PC program which allows Counterpart users to add, edit, and access IDs over a network connec
Counterpart User Manual - Scale Operations 495.6 Totalization CountsCounterpart has a totalization function that allows you to totalize the quantity o
50 Counterpart User Manual5.8 Connecting a Barcode ScannerThe Counterpart will accept a barcode scanner connected to the unit. In order to use a scann
Counterpart User Manual - Serial Commands 516.0 Serial CommandsThe Counterpart can be controlled by a PC or remote keyboard connected to an indicator
52 Counterpart User Manual6.1.2 Keypad LockThe user has the ability to lock or unlock the keypad. The commands are listed in Table 6-2.6.1.3 ID Comman
Counterpart User Manual - Serial Commands 536.1.5 Reporting CommandsReporting commands send specific information to the serial port. The commands list
iv Counterpart User Manual
54 Counterpart User ManualCommand Description ValuesSC.GRADS#n Graduations 1–100000SC.ZTRKBND#n Zero track band 0, 0–100SC.ZRANGE#n Zero range 1.90000
Counterpart User Manual - Serial Commands 55EDP.ECHO#p Port echo ON, OFFEDP.EOLDLY#p Port end-of-line delay 0–255 (0.1-second intervals)EDP.HEADERS#p
56 Counterpart User ManualREG.BASE Zero base for overload calculation CALIB, SCALE REG.PRTMOT Allow print while in motion NO, YESREG.PRINTPT Add PT to
Counterpart User Manual - Serial Commands 576.1.8 Normal Mode CommandsThe normal mode print commands (see Table 6-12) transmit data to the serial port
58 Counterpart User Manual7.0 Print FormattingThe Counterpart provides eight print formats, GFMT, NFMT, TOTALFMT, PALFMT, CFMT, ACCFMT, HDRFMT1 andHDR
Counterpart User Manual - Print Formatting 59Command DescriptionSupported Ticket Formats<G> Gross weight in displayed unitsGFMT, NFMT, TOTALFMT,
60 Counterpart User ManualThe 500-character limit of each print format string includes the output field length of the print formatting commands, not t
Counterpart User Manual - Print Formatting 61The default Counterpart print formats are shown in Table 7-2 and Table 7-3:7.2 Customizing Print FormatsT
62 Counterpart User ManualFigure 7-1. PFORMT Menu, Showing Alphanumeric Character Entry Procedure7.2.3 Using Revolution® The Revolution configuration
Counterpart User Manual - Print Formatting 637.2.4 Print Label ExamplesListed below are print formatting examples that appear with the various formats
Counterpart User Manual - 1About This ManualThis manual is provided for the use of trained and qualified installers of counting scales, and represent
64 Counterpart User ManualTotal Label FormatFigure 7-6. Total Format Label ExampleGross/Tare/Net Label FormatFigure 7-7. Gross/Tare/Net Label Format
Counterpart User Manual - WLAN Installation Instructions 658.0 WLAN Installation InstructionsBefore installing this option, you must contact your IT a
66 Counterpart User Manual9.0 Appendix9.1 Error MessagesIf an error code appears on the display, use the information in Table 9-1 as a troubleshooting
Counterpart User Manual - For More Information 67Table 9-2. Error Codes Returned on XE Command9.2.1 Using the P EDP CommandThe P EDP command returns t
68 Counterpart User Manual9.3 Continuous Output (Stream) FormatFigure 9-1 shows the continuous output format sent to a Counterpart port when that port
Counterpart User Manual - For More Information 69<M[G | N | T]> STR.GROSSSTR.NETSTR.TAREMode. Specifies gross, net, or tare weight for the curre
70 Counterpart User ManualB17 Configuration =000 if current DECPNT=8888800=001 if current DECPNT=8888880=010 if current DECPNT=8888888=011 if current
Counterpart User Manual - For More Information 719.6 Digital FilteringThe Counterpart uses averaged digital filtering to reduce the effect of vibratio
72 Counterpart User Manual9.6.3 Setting the Digital Filter ParametersFine-tuning the digital filter parameters greatly improves indicator performance
Counterpart User Manual - For More Information 739.7 Serial Scale InterfaceSerial port 1 can be configured for serial scale input. The serial scale fu
2 Counterpart User Manual1.0 IntroductionThe Counterpart offers practical solutions for a full range of precision counting applications. A bright LCD
74 Counterpart User Manual9.8 Regulatory Mode FunctionsThe function of the front panel TARE and ZERO keys depends on the value specified for the REGUL
Counterpart User Manual - For More Information 759.9 Updating FirmwareTo update firmware of the Counterpart, you must have Revolution installed and a
76 Counterpart User ManualFigure 9-5. Rice Lake Updater Screen8. Click the Program button. The update will take several moments. 9. When complete, rem
Counterpart User Manual - For More Information 779.11 SpecificationsPOWER:Power source:Input: 100-240VAC, 47-63 Hz, 5 watts, US power cordOutpu
78 Counterpart User ManualCounterpart Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installe
Counterpart User Manual - For More Information 79For More InformationLiterature• Counterpart Sales Literature, PN 125545• Counterpart CD with WeighVau
PN 118677 06/11
Counterpart User Manual - Introduction 31.4 Keypad Functions Key Function POWERTurns the Counterpart unit on/off.NOTE: If the PC1 jumper is set
Komentarze do niniejszej Instrukcji