Rice Lake 740-10-2 Series Instrukcje Operacyjne

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Wagi kuchenne Rice Lake 740-10-2 Series. Rice Lake 740-10-2 Series Operating instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Instructions

118556Digital Veterinary/Platform Scale740-10-2 SeriesSoftware Revision 11387Technical and Operating InstructionsTo be the best by every measure

Strona 2

6 Veterinary/Platform Technical and Operating Instructions3.3 Using the Tare FunctionYou can use the tare function for deducting an extra weight (suc

Strona 3 - Contents

Veterinary/Platform Technical and Operating Instructions - Scale Configuration 74.0 Scale ConfigurationOptions and parameter setup are done through t

Strona 4

8 Veterinary/Platform Technical and Operating InstructionsVarious parameters can be set up while in configuration mode. Power Off Power On-Off START

Strona 5 - 1.0 Introduction

Veterinary/Platform Technical and Operating Instructions - Scale Configuration 9The following table lists the various display messages and sequence w

Strona 6 - 2.0 Scale Assembly

10 Veterinary/Platform Technical and Operating Instructions13 Message style on weight algorithmMESS <-> WEIGH This displays the message that wi

Strona 7 - Load Cell Connections

Veterinary/Platform Technical and Operating Instructions - Scale Configuration 11Option 5 allows for live or dynamic weighingOP5 = 0 Hold the Kg-Lb k

Strona 8 - 3.0 Scale Operation

12 Veterinary/Platform Technical and Operating Instructions4.4 Reset To Factory DefaultsThe configuration parameters may be reset to factory defaults

Strona 9

Veterinary/Platform Technical and Operating Instructions - Scale Calibration 135.0 Scale CalibrationBefore you can calibrate the scale, verify and se

Strona 10 - 3.3 Using the Tare Function

14 Veterinary/Platform Technical and Operating Instructions6.0 RS-232 CommunicationThe scale comes with an RS-232 port which enables weight data to b

Strona 11 - 4.0 Scale Configuration

Veterinary/Platform Technical and Operating Instructions - RS-232 Communication 156.3 ESC Protocol (configuration option #9 set to 0)The ESC Protocol

Strona 13

16 Veterinary/Platform Technical and Operating Instructions3. Double click on the Rswin.exe file and the following screen appears.Click on FILES and

Strona 14

Veterinary/Platform Technical and Operating Instructions - RS-232 Communication 17Examples of what you would see in the HEX screen are shown in Figur

Strona 15

18 Veterinary/Platform Technical and Operating Instructions6.4 Sample and Explanation of ESC ProtocolWhen the scale measures weight and sends this ov

Strona 16 - 4.4 Reset To Factory Defaults

Veterinary/Platform Technical and Operating Instructions - RS-232 Communication 19If the battery is okay, the scale will reply with the following val

Strona 17 - 5.0 Scale Calibration

20 Veterinary/Platform Technical and Operating Instructions7.0 Troubleshooting and TestingRefer to the following instructions to check and correct an

Strona 18 - 6.0 RS-232 Communication

Veterinary/Platform Technical and Operating Instructions - Troubleshooting and Testing 217.1 Test ModeThe test mode menu is a special mode used for c

Strona 19

22 Veterinary/Platform Technical and Operating Instructions5Checks for current battery levelbAt <-> XXX or nO bAt If the nO bAt is displayed, t

Strona 20 - Figure 6-1. Rswin Screen

Veterinary/Platform Technical and Operating Instructions - Troubleshooting and Testing 237.2 Trimming ProcedureTrimming is the process of equalizing

Strona 21

24 Veterinary/Platform Technical and Operating Instructionsusing the corresponding potentiometer, turn each cell down to equal the referenced load ce

Strona 22 - %JBHOPTFCBUUFSZ

Veterinary/Platform Technical and Operating Instructions - Maintenance 258.0 MaintenanceThe following section provides instructions for maintaining a

Strona 24

26 Veterinary/Platform Technical and Operating Instructions9.0 Veterinary/Platform Scale SpecificationsPower120 VAC-9VDC-50Hz / 230 VAC-9VDC-50HzBatt

Strona 25 - 7.1 Test Mode

Veterinary/Platform Technical and Operating Instructions - Veterinary/Platform Scale Specifications 27For More InformationSystem Manuals• Veterinary/

Strona 26 - Table 7-2. Test Mode Menu

28 Veterinary/Platform Technical and Operating InstructionsDigital Veterinary/Platform Scale Limited WarrantyRice Lake Weighing Systems (RLWS) warran

Strona 28

PN 118556 11/10

Strona 29 - 8.0 Maintenance

ii Veterinary/Platform Technical and Operating InstructionsRice Lake continually offers web-based video training on a growing selection of product-re

Strona 31 - For More Information

2 Veterinary/Platform Technical and Operating Instructions2.0 Scale Assembly2.1 Unpacking Your ScalePlace the unopened box in an open area that has a

Strona 32

Veterinary/Platform Technical and Operating Instructions - Scale Assembly 3Battery ChargingWhen the AC adaptor is connected to a power source, the re

Strona 33

4 Veterinary/Platform Technical and Operating Instructions3.0 Scale OperationThe display has various front panel keys. They are shown below.Figure 3-

Strona 34 - PN 118556 11/10

Veterinary/Platform Technical and Operating Instructions - Scale Operation 53.2 Using the Body Mass Index (BMI) FunctionBody mass index (BMI) is the