Configuration
Step
Values
Set
Description
Print Response Retry Time-out for the bi-directional Remote
Printer Communication
TMO
This choice is only available when setting C3.5 “TYP”=RP
0
Disable (Use Internal Default Retry Time-out)
C3.10
1~255
1=10 milliseconds (Should be at least 5=50ms)
C4 Filter/Motion
AVG
Average, Digital Filter
C4.1
1 ~ 8
Default = 4 (8 = Maximum Stability)
MOW
Motion Window (1 = 0.5 Division)
0 = No Motion Check
C4.2
0~255
Default = 1
MOT
Motion Time ( 1 = 0.1 sec )
C4.3
0~255
Default = 5
C5 Pre-calibration
CUN
Calibration Unit Selection
KG
To Calibrate by kilogram “kg”
LB
To Calibrate by pound “lb”
G To Calibrate by gram “g”
C5.1
OZ
To Calibrate by ounce “oz”
SUN
Secondary Conversion Weight Unit
KG
To set secondary weight unit as kilogram “kg”
LB To set secondary weight unit as pound “lb”
G
To set secondary weight unit as gram “g”
C5.2
OZ
To set secondary weight unit as ounce “oz”
MET
Metrology Method
OIM OIML (F.S. Capacity + 9 divisions, 2% Zero Range, etc.)
C5.3
USA
USA (F.S. Capacity + 5%, 100 % Zero Range, etc.)
DP
Decimal Point Position
C5.4
0 ~ 4
Default = 0, (No Decimal Point)
CAP Capacity Setting
C5.5
Display will show “C XXX.XX”,
Default = 10000 lb
DIV
Count-by
Default = 1.
C5.6
1, 2,
5,10,
20, 50,
100
Select any one of 1, 2, 5, 10, 20, 50 and 100.
AZT
Auto Zero Tracking Width (In Divisions)
OFF
Auto Zero Tracking function is
OFF
0.5D
To
C5.7
3.0D
Select any one of 0.5D through 3.0D